MEMBRANE

Features :

DOW FILMTEC™ brackish water reverse osmosis membrane elements provide consistent, outstanding system performance in light industrial applications.

  • DOW FILMTEC LE-4040 delivers highest performance at lowest pressure resulting in less energy usage and lower costs.
  • DOW FILMTEC BW30-4040 is the industry standard for reliable operation and production of the highest quality water.
  • DOW FILMTEC BW30-2540 elements are designed for systems smaller than 1 gpm (0.2 m3/h) offerlng a hard shell exterior for extra strength.

 

Elements with a hard shell exterior are recommended for systems with multiple-element .housings containing three or more membranes. as they are designed to withstand hig_her pressure drops.

 

 

Polyamide Thin-Film Composite 113°F (45°C)

600 psi (41 bar)

16 gpm (3.6 m3/h)

6 gpm (1.4 m3/h)

15 psig (1.0 bar)

2 -11

1 -13

SOI 5

<0.1 ppm

 

Operatlng Limlts

 

  • Membrane Type                                                      
  • Maximum Operating Temperaturea
  • Maximum Operating Pressure
  • Maximum Feed Flow Rate - 4040 elements

                                           - 2540 elements

  • Maximum Pressure Drop
  • pH Range, Continuous Operationa
  • pH Range, Short-Tenn Cleaningb
  • Maximum Feed Silt Density Index
  • Free Chlorine Tolerancec

 

Important Information

Proper start-up of reverse osmosis water treatment systems is essential' to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters confonn to design specifications so that system water quality and productivity goals can be achieved.

Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.

Please refer to the application infonnation literature entitled "Start-Up Sequence" (Fonn No. 609- 02077) for more informâtion.

 

Operation Guidelines

Avoid any abrupt pressure or cross-flow variations on the spiral elements during start-up, shutdown, .cleaning or other sequences to prevent possible membrane damage. During start-up, a graduai change from a standstill to operating state is recommended as follows:

  • Feed pressure should be increased graduaily over a 30-60 second time frame.
  • Cross-flow velocity at set operating point should be achieved gradually over 15-20 seconds.
  • Penneate obtained from first hour of operation should be

 

 

General Information

  • Keep elements moist at all tlmes after initial wetting.
  • If operating limits and guldelines glven in this bulletin are not strictly followed, the llmited warranty will be null and void.
  • To prevent biological growth during prolonged system shutdowns, it is recommended that membrane elements be lmmersed in a preservative solution.
  • The customer is fully responsible for the effects of incompatible chemicals and lubricants on elements.
  • Maximum pressure drop across an entfre pressure vessai (housing) is 50 psi (3.4 bar).
  • Avoid statlc penneate-side backpressure at all times.

 

Regulatory Note

These membranes may be subJect to drinking water application restrictions in some countries: please check the application status before use and sale.